  1. The requirements for smoke detector installation do not apply to day care centers housed completely within one room. Also note that the detectors are not allowed to be battery operated - they must be powered by the building's electrical system and be part of an interconnected fire alarm system.

  2. Overview. NFPA 72 is a publication for the design, installation, testing, inspection, and maintenance of fire alarm systems, emergency communication systems, and other signaling systems. The Illinois Fire Alarm Code 2019 is based on the NFPA 72, 2019.

    • Fire Alarm and Sprinkler Requirements For Lodging Or Rooming Houses
    • Fire Alarm and Fire Sprinkler Requirements For Dormitories and Hotels
    • Transient Establishments Require Integrated Testing
    • International Fire Code Requirements For Group R Occupancies

    If an existing lodging or rooming house has a smoke detection system that is properly maintained and tied to a fire alarm box that can activate the system, then a complete fire alarm system does not need to be installed. Some exceptions and allowances within codes allow the installation of only smoke detectors, or only a single manual pull station....

    New dormitories and hotels require a fire alarm system. Functions of the fire alarm system specific to dormitory and hotel occupancies include requirements for the following features: 1. Manual fire alarm box, or pull stations. 2. Manual fire alarm box located at a continuously supervised location. 3. Required to be initiated by activation of the f...

    A lodging facility, rooming house, dormitory, or hotel all require integrated testing. Integrated testing, introduced in the 2018 edition of the Life Safety Code, is needed to ensure that all functions of a variety of intertwined building systems take place during system activation. Integrated fire systems are those fire protection and life safety ...

    The IFC requires the installation of a fire sprinkler system throughout all Group R occupancies. If the facility is a Group R-3, the IFC permits the installation of a less complex NFPA 13D fire sprinkler system vs. an NFPA 13 version. Fire alarm systems are also required to be installed throughout all Group R-1, and Group R-2 occupancies — though w...

  3. sfm.illinois.gov › resources › life-safety-codeLife Safety Code - Illinois

    The Office of the State Fire Marshal (OSFM) updated its administrative rules, which, in part, updates the adopted life safety code from the NFPA 101, Life Safety Code (2000 Edition) to the NFPA 101, Life Safety Code (2015 Edition). These changes became effective on January 1, 2020.

  4. NFPA 72 covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire and carbon monoxide detection and warning equipment, and emergency communications systems (ECS), and their components.

  5. A good fire detection and suppression system is a must for any hotel or motel. Water-based fire protection for hotels and motels has been the standard for generations as it is the safest for guests. The challenge? Water damage can be substantial causing an immense amount of damage and repairs.

  6. People also ask

  7. About this chapter: Chapter 9 prescribes the minimum requirements for active fire protection equipment systems to perform the functions of detecting a fire, alerting the occupants or fire department of a fire emergency, mass notification, gas detection, controlling smoke and controlling or extinguishing the fire.