    • Addressable

      • What Is an Output Module in a Fire Alarm System? Output modules are addressable, so they are located on the signaling line circuit and receive input signals from the FACP. Subsequently, when the module receives this input, it can control output devices, emergency controls and activate devices of higher voltages.
      firealarm.com/what-are-emergency-control-function-interfaces/
  1. The Signaling Line Circuit (SLC) for the building wiring for a fire alarm system is the communication and power circuit that is connected between the fire alarm panel and the Addressable Input Modules (AIM) and devices, and the Addressable Output Modules (AOM).

    • Suppression

      -- Alarms for a sprinkler system usually are sent to the...

    • Contact

      www.douglaskrantz.com 6520 Irving Ave So Richfield,...

    • Electronics

      What Causes the Noise in the Sound System?-- To test if it...

    • About

      With fire alarm systems, there is a world-wide need for fire...

    • Life Safety

      -- Firefighting zones and evacuation zones are an integral...

    • Maintenance

      -- Rather than relying on anyone else to remove an old fire...

  2. Mar 3, 2021 · A visual guide and discussion on the major components of a fire alarm system.

  3. To summarize, the functions of control modules in fire alarm systems include: Supervising and monitoring connected devices and wiring; Programming device activations based on fire and emergency detection; Coordinating and centralizing control of the fire alarm system; Enabling communication with other systems

  4. May 8, 2024 · There are two ways to integrate emergency control functions into your fire safety system—by using relays or output modules. Relays are intuitive devices that may be used to activate emergency controls using the notification appliance circuit.

  5. The input/output modules reliably control other equipment, such as door holders, fire dampers, smoke control systems, plant shutdown etc. Whatever the need, our fire protection systems provide the ideal addressable module.

  6. The words Notification Appliance Circuit is a technical term for the output circuit from a conventionally wired fire alarm system. A Conventional NAC has a very specific method of wiring. A horn or strobe has a current blocking diode.

  7. People also ask

  8. Control Module shall provide the dry contact output for activating a variety of auxiliary devices such as PAS, Firefighting equipment, AHUs, and conventional devices as required. These are typically used where control or shutting of external equipment is required.