      • What Is an Output Module in a Fire Alarm System? Output modules are addressable, so they are located on the signaling line circuit and receive input signals from the FACP. Subsequently, when the module receives this input, it can control output devices, emergency controls and activate devices of higher voltages.
      firealarm.com/what-are-emergency-control-function-interfaces/
  1. The Signaling Line Circuit (SLC) for the building wiring for a fire alarm system is the communication and power circuit that is connected between the fire alarm panel and the Addressable Input Modules (AIM) and devices, and the Addressable Output Modules (AOM).

    • Suppression

      -- Alarms for a sprinkler system usually are sent to the...

    • Contact

      www.douglaskrantz.com 6520 Irving Ave So Richfield,...

    • Electronics

      What is the Difference Between Thermostat and Fire Alarm...

    • About

      With fire alarm systems, there is a world-wide need for fire...

    • Life Safety

      -- Firefighting zones and evacuation zones are an integral...

    • Maintenance

      -- Rather than relying on anyone else to remove an old fire...

  2. Mar 3, 2021 · A visual guide and discussion on the major components of a fire alarm system.

  3. May 8, 2024 · There are two ways to integrate emergency control functions into your fire safety system—by using relays or output modules. Relays are intuitive devices that may be used to activate emergency controls using the notification appliance circuit.

  4. Key Takeaways: A control module is a vital component of a fire alarm system, responsible for the supervision and monitoring of devices and circuits. Control modules provide centralized control and monitoring capabilities when used in conjunction with fire alarm control panels.

    • Codes and Standards
    • Selection Criteria of FDAs Components
    • Fire Alarm Control Panel
    • Fire Alarm Repeater Panel
    • Graphical User Interface (Gui) with Workstation
    • Multi Sensor Detector
    • Manual Call Point
    • Hooter with Strobe
    • Monitor Module
    • Control Module

    The basic design will conform to the requirements of the latest editions of the following codes, guides and specifications wherever applicable.

    Criteria for selecting fire detectorsand devices considering the various areas of the plant should be as follows:

    Loop supervision
    Alarm generation from detector/ devices
    Functional alarms such as a low battery, AC power failure, fault
    Connection to detectors/ devices through loop cable
    Passive type
    Alpha-numeric display
    Controls like alarm silence, alarm reset & alarm acknowledge.
    Repeat alarm signals from the FACP that are connected to the network.
    PC-based GUI shall be provided with customized software.
    Seamless integrated graphical mimicwith full alarm management and panel control capability.
    Installation plans, device type, locations, zoom areas, and zoom magnifications shall be able to import from AutoCAD as loaded in GUI.
    Software shall be able to generate audio-visual indications in case of emergency/ input signals from detectors/ devices/ panels.
    The detectors should be intelligent addressable & loop powered.
    Each detector shall use state-of-the-art microprocessor circuitry with error, detector self-diagnostics, and supervision programs.
    Each detector should have a multicolor & multi-status indicator LED to indicate the status of the detector.
    It should be surface wall or pole mounted indoor and outdoor type for a safe area.
    If conventional MCPs provided, the same shall be made addressable using the monitor module.
    Ex-proof MCPs must be provided in hazardous areas.
    Hooter with Strobe should be addressable & loop powered.
    Hooter should sound automatic when any of the detectorsin that zone detects a fire condition.
    Hooter should be installed considering sound pressure level, and acoustic area coverage.
    If a conventional Hooter/ strobe is provided, the same should be made addressable using the control module.
    Monitor Module shall supervise the open potential free dry contact input of the device & give an alarm when the alarm is generated by the connected device.
    The monitor module shall be the interface between FACP & DCS, FACP & conventional devices to make them addressable one
    Control Module shall provide the dry contact output for activating a variety of auxiliary devices such as PAS, Firefightingequipment, AHUs, and conventional devices as required. These are typically...
    Control relay modules shall be provided to integrate FDAS with third-party systems.
  5. Addressable modules intelligently connect independent, potential-free make or break contacts. Two kinds of addressable modules are available: input modules and input/output modules. Input modules monitor devices responsible for alarm inputs and confirm signals or technical states etc.