Nov 25, 2021 · Related dose and image quality data should be stored together in a database to provide fast query access for a high-performance user interface, including data analysis, data visualization, and report generation functions incorporating interactive charts and dynamic computation results.
- Download Figures (Ppt)
Multi-infrastructure system for data connection and key...
- Reflection, Celebration, Inclusion
The Journal has exceeded even my lofty expectations. We have...
- Download Figures (Ppt)
Oct 17, 2022 · The optimal imaging protocols should be developed and established with the help of a medical physicist to obtain consistently high image quality at the minimum possible radiation dose. The images should be properly compressed for transmission and storage without loss of significant clinical data.
- Aparna Tompe, Kiran Sargar
- 2022/10/17
- 2020
Oct 4, 2017 · In practice, it involves compromising between the image quality and dose to the patient; the dose should not be higher than necessary to achieve an image quality (or diagnostic information) needed for the clinical task. Monitoring patient dose is a key requirement toward optimization.
- Hannu Järvinen, Jenia Vassileva, Ehsan Samei, Anthony Wallace, Eliseo Vano, Madan Rehani
- 2017
Jun 14, 2018 · The paper also examined elements of best practices for digital image quality and dose reduction techniques in digital radiography (DR) from a radiographer perspective. In 2018, the ASRT convened a new workgroup to update and revise the 2012 best practice recommenda-tions.
- Lee W Goldman
- 2007
- Standard CT dosimetry phantoms consist of cylindric acrylic phantoms with holes for dosimeter insertion at various locations. The 2 sizes are 16 cm in diameter to represent heads and small pediatric bodies and 32 cm in diameter to represent adult bodies.
- Phantom insert to hold TLDs used to measure dose profiles. TLDs are close together within x-ray primary beam and are farther apart to measure profile tails.
- Example of doses measured by TLDs inside phantom for a 10-mm slice thickness, plotted as function of TLD position along z-axis. This type of plot is referred to as a dose profile.
- Cumulative dose from a series of contiguous slices is known as multislice average dose (MSAD). Dose-profile tails extend quite far from center of x-ray beam and thus contribute radiation dose to nearby slices.
Apr 1, 2023 · Overexposure without effective improvement in image quality can produce high dose levels that adversely affect both diagnostic radiology efficiency and health; therefore, experimental data analysis is a useful, ongoing process for providing information about the adequacy of radiation exposure.
People also ask
Why should dose and image quality data be stored together?
What is a compromising image quality & dose?
What makes a good image quality?
What information should be included in the image data?
What makes a good digital image?
What is captured image data & why is it important?
Dose reduction and image quality improvement of chest radiography by using bone-suppression technique and low tube voltage: a phantom study